Icopal-Roof-Design

Warm Pitched Roof - Unventilated and Sealed

Roof Construction

  • Roof space unventilated and sealed.
  • Thermal insulation following the rafter line.
  • No ventilation to roof space required.
Warm Pitched Roof - Unventilated and Sealed

Benefits Of Sealed Warm Roofs

  • Energy efficient.
  • Decreases air leakage / infiltration.
  • Reduces condensation risk.
  • Minimises the thermal bridge at the eaves.
  • Negates the need for ventilation products.
  • Lower installed cost.
  • Better use of space within the building.
  • Ensures all services are within the heated environment.
  • Eliminates large cool voids within the construction reducing thermal stress.

Eliminating traditional ventilation and the potential condensation risk associated with large voids of cool air make this the optimum pitched roof solution. With the potential of additional living space, a cathedral roof design or a conditioned roof void are rapidly becoming the preferred choice of pitched roof construction in the UK.

In a warm pitched roof construction the thermal Insulation is placed in the rafter line. The position of the Insulation can be wholly above or partially between and above the rafter; alternatively it can be positioned between the rafters or partially between and below the rafter.

If the insulation thickness only partially fills the rafter depth the vapour open / permeable underlay should be draped over the rafter in the traditional method. The underlay should not be allowed to touch the surface of the Insulation and a clear air space ensured between the membrane and insulation. Should the vapour permeable underlay be laid directly on top of the insulation in a fully supported situation it should be secured by counter battens to allow water to drain effectively across the membrane surface and from the roof.

To achieve a truly sealed roof all laps in the underlay, all penetrations and all junctions must be sealed with Monotape.

To avoid water ponding behind the fascia and to prevent long term exposures of the underlay to ultra-violet radiation install Monarflex EavesGuard.

A vapour control layer must be used directly above the internal ceiling to prevent water vapour entering the roof envelope and to achieve air tightness of the habitable space as required by Approved Document L Building Regulations 200.

Choose The Right Underlay

The following membrane types can typically be used:

  • Monarperm Breathe
    • Contact Icopal 0161 8654444

      Find Local Support

      To discuss your project in more detail please contact
      Your Local Area Manager

       

      Technical Support

      Telephone:

      0330 123 4585

      Email: technical.uk@bmigroup.com

       

      Sales Enquiries & Orders

      Telephone:

      0843 224 7400

      Fax:

      0843 224 7401

      Email: sales.admin@bmigroup.com

      Latest News

      BMI crowns the highest building in the West Country

      Read more...

      Winners and contenders alike praise the BMI Apprentice of the Year competition

      Read more...

      BMI National Training Centre flattens Ceiran’s learning curve

      Read more...

      Complexity simplified with BMI Icopal’s Total Torch system curve

      Read more...

      BMI’s apprentice competition demonstrates its commitment to roofing’s future

      Read more...

      BMI UK & Ireland launches to the UK construction industry

      Read more...

      This site uses cookies in accordance with our Website Privacy Policy. By continuing to browse the site you are agreeing to our use of cookies. To browse without the use of cookies, you can opt-out as explained in our Website Privacy Policy or adjust your cookie settings for your browser

      Icopal: We Protect Your Building