Vertical Terminations & Fixing Bars

Vertical Terminations & Fixing Bars

Terminate the single ply roofing membrane to the specified height, ensuring a minimum 150mm height is maintained. Where units on kerbs can be raised, it is recommended that the curbs be raised to achieve the 150mm minimum height.

Terminate the top of all flashing as per the Monarplan details. Where the flashing is not protected by a cover flashing, a surface mounted Termination Bar must be installed. Flashing must not be installed over weep holes or damp proof courses in brick walls. Terminate flashing just below weep holes and damp proof courses.

Use Monarplan Fixing Bar to mechanically fasten Monarplan membrane at perimeters, angle changes etc or when using a peel stop detail.