Monarplan Single Ply Roofing

Video Tutorial – Forming Standing Seams In Single Ply Roofing Membranes

Monarplan Standing Seams can improve the aesthetic appearance of a single ply roof. The video shows how to weld Monarplan Standing Seams to the underlying Monarplan PVC single ply roof membrane.  

 

Video Transcript
Position the standing seam length at the appropriate centres. Using a straight edge, push the standing seam in position and spot weld.

In a continuous motion, weld the horizontal edge of the standing seam to the single ply roofing membrane using a penny roller and 20mm nozzle attached to the hot air welder.

Repeat the welding process for the opposite edge ensuring continuous full welds are achieved on both sides. 
 

    Contact Icopal 0161 8654444