Icopal Universal Single Ply Roof Membranes - Application Methods

Methods of Application

With today’s construction trends of highly intricate and complex structures and the requirement for higher thermal insulation values, only membranes which aspire to the highest quality standards and possess unquestionable technical properties, will be considered in the design process. The versatility of Icopal Universal® ensures the designer total freedom and security when specifying the roof waterproofing system .

Mechanically Fastened System

Mechanically fixed single ply roof systems are often favoured above timber or metal decks where the exposure of the fastener on the underside of the structure is not a consideration. This method of application involves the use of thermally broken fasteners fixed at pre-determined centres and is a fast and cost effective method of installing the single ply membrane which is less dependent upon amicable weather conditions.

Membrane used: Icopal Universal

Mechanically fixed single ply roof systems

Mechanically Fastened Systems
 

Fully Adhered System

Fully adhered single ply roofing systems are more commonly used above concrete substrates where the process of installing mechanical fixings is invasive and labour intensive. Fully adhered systems are reliant upon suitable weather conditions (which should be considered) however, complex geometries and pitched surfaces can be accommodated with great success. Fully adhered membranes can also provide a superior surface finish.

Membranes used: Icopal Universal , Icopal Universal WS (beneath green roofs)

Fully adhered single ply roofing systems
Fully Adhered Systems

Ballasted Roof System

In ballasted systems the waterproofing membrane is loose-Iaid and welded together at the overlaps prior to the application of a ballast which holds the membrane in place. This method offers maximum restraint to wind uplift and fast application times, while providing protection from mechanical and solar/UV damage.

The single ply roofing membrane can be placed above the insulation in a warm ballasted roof buildup.

Warm Ballested Roof System

Warm Ballasted Roof System

Alternatively, the membrane may be used in an inverted warm roof situation, where the insulation is placed above the waterproofing. These inverted ballasted systems also provide maximum resistance against membrane damage, UV degradation, thermal shock, fire and noise.

Ballasted roof systems offer an excellent solution for situations where access or recreation is a priority.

Membranes usedIcopal Universal and Icopal Universal WS (beneath green roofs)

Inverted Warm Ballested Roof

Inverted Warm Ballasted Roof System

    Contact Icopal 0161 8654444

    Find Local Support

    To discuss your project in more detail please contact
    Your Local Area Manager

     

    Technical Support

    Telephone:

    0330 123 4585

    Email: technical.uk@bmigroup.com

     

    Sales Enquiries & Orders

    Telephone:

    0843 224 7400

    Fax:

    0843 224 7401

    Email: sales.admin@bmigroup.com

    This site uses cookies in accordance with our Website Privacy Policy. By continuing to browse the site you are agreeing to our use of cookies. To browse without the use of cookies, you can opt-out as explained in our Website Privacy Policy or adjust your cookie settings for your browser

    Icopal: We Protect Your Building